Make the sprinklers you already have work harder.

Water is not a better material for fire suppression. Yet, many places use neat water to run through sprinklers for the fire control. Deapite the high performance fire control materials & foams, water is used due to cost. To address this, MicellEx is a low-cost additive that fits onto your existing sprinkler riser. Just 1% mixing boosts the water performance.

With MicellEx~30 dynes/cmSpreads and soaks in Plain water~72 dynes/cmBeads up and runs off
About 1%dose mixed into sprinkler water
100 L tankdoses about 10,000 L of water
No electric pumpruns on the water’s own pressure
Fluorine-freeno PFAS, PFOA or PFOS

Why plain water falls short

Water is a good coolant, but it is not built for today’s stock rooms and shop floors.

It beads up

With high surface tension, water sits on top of cartons, textiles and timber instead of reaching deep-seated embers.

It runs off

On walls and vertical racks, water drains to the floor and leaves surfaces exposed to radiant heat.

It struggles with plastics and batteries

Burning plastics and lithium-ion packs repel water, and long sprinkler run times can soak stock the fire never reached.

How MicellEx changes the water

It works through standard deflector-plate sprinkler heads and needs no aeration.

It wets

Lowers surface tension from about 72 to about 30 dynes/cm, so droplets spread across hot surfaces and wick into cardboard, wood and fabric.

It clings

Forms a light froth that helps water stay on vertical surfaces and adds a wet barrier against radiant heat.

It encapsulates

Micelles form around hydrocarbon fuels and molten plastics, helping to cool them and hold back flammable vapours.

See the difference side by side

Two demonstrations, one with wood and one with plastic, each comparing plain water with MicellEx water.

[YouTube Short: wood fire demo]

Wood fire test

This video demonstrates faster mitigation of wood fire with MicellEx. Clean water (in purple spray) and 1% MicellEx formulation (in green spray) is sprayed side by side. MicellEx suppresses the fire in about half amount. You can test with the sample yourself.

Fuel
Stacked wood chips & sticks, dry leaves and paper
Quantity
2 kg each
Spray method
Hand sprayer at equal distance. After MicellEx wins, plain water spray brought closer.
Water used
1 L each, MicellEx used 58 ml while neat water needed was 115 ml

[YouTube Short: plastic fire demo]

Plastic fire test

This We see faster mitigation of plastic fire with MicellEx. Clean water (in purple spray) and 1% MicellEx formulation (in green spray) is sprayed side by side. MicellEx suppresses the fire in about half amount. You can test with the sample yourself.

Fuel
Mixed plastic packaging including PET bottles, HDPE cap, LDPE & laminate pouch.
Quantity
60 g each
Spray method
Hand sprayer at equal distance. After MicellEx wins, plain water spray brought closer.
Water used
1 L each, MicellEx used 19 ml while neat water needed was 48 ml

Demonstrations show specific conditions and performance would vary in every fire. Results depend on fuel, delivery and environment. Hence we urge the users to test the sample in their existing processes.

Test it on your own fire, free

We’ll send you a free sample. Blend about 1% into water, then compare plain water against MicellEx water on the fuel, spray method and conditions that matter to you.

1% = 10 mL per litre of water

We will send you 100 ml to 200 ml formulation that suffices for upto 20L water preparation. You can blend say 100 ml in 10 L, and then spray it on any fire to test. It's better to use similar fire/flames and compare the results with plain water simultaneously or immediately.

Request your free sample

  1. Request the sample

    Tell us your fuel, how you plan to spray it, and where to send the pack.

  2. Blend about 1%

    Mix the concentrate into clean water. No special equipment is needed.

  3. Run a side-by-side test

    Use the same fuel, quantity, spray method and water volume for plain water and for MicellEx water.

  4. Share what you see

    Send us your results or videos and we’ll help plan a full site assessment.

For a fair comparison

  • Change one thing only: plain water or MicellEx water.
  • Match fuel amount and arrangement, nozzle or sprayer, distance and water volume.
  • Time each test and record video.

Test outdoors or in a controlled area, with protective equipment and extinguishing means ready. Results vary with fuel, delivery and conditions.

A retrofit that happens in the riser room

  1. Install the dosing tank

    Fitted at the main sprinkler riser, downstream of the alarm check valve. The store or plant keeps running.

  2. A sprinkler opens

    Water flow draws in a calibrated dose of about 1% MicellEx, using the water’s own pressure.

  3. Treated water reaches the fire

    Every existing sprinkler head now delivers water with changed spreading and wetting behaviour.

  4. Less water, less damage

    When water works harder, sprinklers can be shut off sooner, which helps protect stock from water damage.

Built for buildings that already have water sprinklers

  • Retail stores
  • Malls and shopping centres
  • Warehouses and logistics
  • Factories
  • Offices and commercial buildings
  • Hotels and hospitals

Lower running cost

Domestically sourced chemistry keeps refill costs low.

Zero shutdown to install

No closing the premises, no ceiling tiles removed, no pipe replacement.

Made for modern fuels

Designed to improve water’s performance on plastics, synthetics and electronics. Test data to follow.

Specifications

Dose rateAbout 1% by volume of sprinkler water
Tank sizingA 100 L tank doses about 10,000 L, typically enough for multiple heads during the first 15 to 20 minutes
Treated surface tensionAbout 30 dynes/cm (plain water is about 72)
Install pointSprinkler riser, downstream of the main alarm check valve. Venturi or Bladder pump are tw choices for the passive operation.
FootprintAbout 0.5 m² for a standard 100 L vertical tank
PowerNone. Mechanical dosing driven by water pressure
CompatibilityStandard deflector-plate sprinklers, no aeration required. Formulated with corrosion inhibitors for steel and brass piping; confirmed for your system at assessment
ChemistryFluorine-free, with no PFAS, PFOA or PFOS
MaintenanceAnnual visual check of bypass valves. Fluid sampling every 3 years
Safety and environmentNon toxic to human and animals. All the constituents are biodegradable.

Questions we hear often

Do I need to replace sprinkler heads or pipes?

No. The dosing tank fits at the riser. Your existing heads and piping stay as they are.

Does it need electricity?

No. The tank doses using pressure from the parent water, so a power cut does not stop it.

Does it replace my fire safety system?

No. It upgrades the water your existing sprinklers deliver. We work with your fire consultant and any required approvals before installation.

Is it safe for my piping?

It is formulated with corrosion inhibitors for steel and brass. During the assessment we confirm compatibility with your specific pipework.

How do I mix and test the free sample?

Blend about 1% (10 mL per litre) into clean water, then compare it with plain water using the same fuel, spray method and conditions.

Can I test it on my own fuel and spray setup?

Yes, that is the point of the sample. Test outdoors or in a controlled area, with protective equipment and extinguishing means ready.

What happens in a site assessment?

We inspect the riser room, review your sprinkler system and building type, size the tank, and send you a quote. Expect our revert within a week.

Request a free sample or site assessment

Tell us what you want to test or protect and we will get back to you with next steps.

Phone
+91 9764793679
WhatsApp
+91 9673543335
Email
info@kalpasrusti.com
Address
C7, Govinda, Rameshwar Nagar, Gangapur Road, Nashik 422 013